Empire Whole House Heating - Floor Furnace: 5088
|
|
|
|
|
-
Register Color: Tan
-
45,000 BTU Input
-
Register Dimensions: 36-3/4" L x 24-3/4" W
-
Casing Dimensions: 34" L x 22" W
-
Overall Length Including Diverter: 43-1/2"
-
Floor Opening: 34-5/16" L x 22-5/16" W
-
Height: 25-3/4"
-
Shipping Weight: 128 lbs.
-
Millivolt Wall Thermostat included
-
Minimum Clearances to Combustibles From:
-
Each side to nearest wall: 6"
-
Bottom of unit for air: 6"
-
Draft diverter and vent connector: 6"
-
Two adjoining sides to walls: 18"
-
Top must be open and clear of all objects and covering
-
Gas Inlet:
-
Type of gas (state on order) LP or N/G
-
Iron pipe size (N.P.T): 1/2"
-
Inlet to Floor: 20-1/4"
-
Venting:
-
Floor to top of diverter shield: 12-1/4"
-
Center of flue to floor covering: 18-5/8"
-
Size of flue collar: 4" diameter
The flue pipe diameter must be as large as the flue collar on the draft
diverter and run as directly as possible to the chimney at least 1/4" ride
per foot of run, properly supported by metal straps, and enter the chimney
so the end of the flue pipe is flush with the inner wall of the chimney.
Any flue pipe passing through walls and roof must be "B" type vent.
The chimney must extend at least two feet above the roof and any object
or building within 10 feet of the chimney. The flue pipe must NOT
have any open tees or be connected to the chimney of an existing fireplace.
Safety Control: Pilot and main burners include automatic
shutoff, temperature limit controls, flood pan and debris pan.
Warranty: Combustion chamber carries a 10-year limited
warranty. All other parts carry a 1-year limited warranty.
For Your Safety: Read your owner's
manual for further safety information
|
Due to high temperatures, the appliance should be located
out of traffic and away from furniture and draperies. Children and
adults should be alerted to the hazard of high surface temperature and
should be kept away to avoid burns or clothing ignition. Installation
and repair should be done by a qualified service person. This series
is design certified by the American Gas Association Laboratories as a floor
furnace ANSI21.48-1992 to be installed according to instructions.
The installation must conform to local codes. In the absence of local
codes, the installation must conform with American National Standard (National
Fuel Gas Code) known as NFPA54 and ANSIZ223.1 available from the American
National Standards Institute, Inc., 1430 Broadway, New York, NY 10018. |
|
|
|
|
|
|