Empire Classic Cast Iron Gas Stoves |
|
|
|
|
The Classic and Classic AH Cast Iron Stoves, by White Mountain Hearth, are traditionally styled stoves containing a strikingly detailed ceramic fiber gas log
set. The result is an attractive, efficient heater that lends elegance to any decor.
We offer these versatile stoves in five rich porcelain-finishes, plus a flat black model you can leave as is or paint to match any décor. (Requires high-temperature coatings available from White Mountain Hearth and most hearth stores.) The optional stone inlays and matching floor pads add a touch of elegance. Order your Classic Cast Iron stove for natural gas or propane, and take charge with a thermostat, remote control, or remote control thermostat.
|
Empire
Classic cast iron stoves deliver the finest choices in beauty and
comfort while providing you with a cost efficient source of heat. Available in Vent-Free, Direct Vent and B-Vent Models.
AH Classic
- 2 Different Venting styles to make installation easy
-
Choose between five porcelain colors or flat black finish
-
Ceramic fiber log set secures to frame
-
Large fire viewing area
-
Variable heat output
-
Manual, wall switch, wall thermostat or remote control
operation
-
Approved as a heater to the A.F.U.E. standard
-
Operates without electricity
-
Push-button ignition
-
Optional automatic blower
-
Safe operation with auto shut-off controls
-
Temperature Control For All Models- On/Off Millivolt
|
|
|
|
|
Empire AH Classic Firebox (Requires Stove Casting)
|
|
|
|
|
A
firebox / burner system, a stove casting, and a cast iron insert or a
stone insert is required for a complete AH Classic Stove. |
AH Classic Models
(On / Off Millivolt)
|
Model
| Venting Type
| | |
BC-2500 | B-Vent
30,000 BTUs | | |
The installation must conform with local codes, or, in the absence of
local codes, with the National Fuel Gas Code, ANSI Z223.1/
NFPA54*.
*Available from the American National Standards Institute, Inc., 11
West 42nd St., New York, NY 10036.
State of Massachusetts: The installation must be made by a
licensed plumber or gas fitter in the Commonwealth of
Massachusetts.
|
|
|
|
|
Empire Insert (Requires Firebox / Burner System & Stove Casting) |
|
|
|
|
A
firebox / burner system, a stove casting, and a cast iron insert or a
stone insert is required for a complete AH Classic Stove. |
Cast Iron Insert |
Model | Description
| | |
CT-2500-BG |
AH Cast Iron Insert: Porcelain Beige
|
|
|
CT-2500-BK |
AH Cast Iron Insert: Porcelain Black
|
|
|
CT-2500-FB |
AH Cast Iron Insert: Painted Flat Black
|
|
|
CT-2500-GR |
AH Cast Iron Insert: Porcelain Green
|
|
|
CT-2500-RD |
AH Cast Iron Insert: Porcelain Red
|
|
|
Stone Insert |
Model | Description
| | |
SI-2500-BG |
AH Stone Insert:
Beige Granite
|
|
|
SI-2500-BK | AH Stone Insert:
Black Granite
| | |
SI-2500-BW | AH Stone Insert:
Black & White Granite
| | |
SI-2500-GR | AH Stone Insert:
Grey Granite
| | |
SI-2500-RD | AH Stone Insert:
Black & Red Granite
| | |
|
|
|
|
|
|
Model |
Description
|
Fits
Model
|
CIB-2 | Automatic Blower
| All models
|
|
|
|
|
|
|
Model | Description
|
GWSG-T |
Wall Thermostat, Millivolt
|
TMV
|
Reed Switch Millivolt Wall Thermostat
|
FRBC |
Battery Operated Remote Control
Click Here For Manual
|
FRBTC |
Battery Operated Remote Control w/Thermostat
Click Here For Manual
|
FREC |
Electric Remote |
FWS-1 |
Wall Switch |
TRW
|
Wireless Remote Wall Thermostat
Click Here For Manual
|
|
|
|
|
|
|
On All Models
Due to high temperatures, the appliance should be located
out of traffic and away from furniture and draperies.
Children and adults should be alerted to the hazards
of high surface temperatures and should be kept away to avoid burns or
clothing ignition.
Installation and repair should be done by a qualified
service person.
The installation must conform to local codes. In
the absence of local codes, the installation must conform with American
National Standard (National Fuel Gas Code) know as NFPA 54 and ANSIZ223.1
(latest edition) available from the American National Standards Institute,
Inc., 11 West 42nd St. New York, NY 10036.
On B-Vent Models
B-Vent models are design certified in accordance with
American National Standard Z21.11.1B- (1995) and CAN1-2.1-M89, CAN/CGA
1.17-M91 by Inchcape Testing/Warnock Hersey Inc., as a Vented Room Heater.
Note: A vent safety switch is standard on all models,
automatically shutting the stove off in the event of a blocked flue or
incorrect installation. (Example: Attaching a 90 degree elbow directly
to the draft diverter is an incorrect installation.) The flue pipe
diameter must be as large as the flue collar on the draft diverter and
run as directly as possible to the chimney with a minimum of elbows.
The horizontal run of flue pipe must slope upward to
the chimney at least 1/4" rise per foot of run, properly supported by metal
straps, and enter the chimney so the end of the flue pipe is flush with
the inner wall of the chimney. Any flue pipe passing through walls
and roof must be "B" Type vent. The chimney must extend at least
two feet above the roof and any object or building within 10 feet of the
chimney. The flue pipe must NOT have any open tees or be connected
to the chimney of an existing fireplace.
|
|
|
|
|