Empire Comfort Systems carries space heaters, blue flame heaters, radiant infrared plaque heaters, vented furnaces, cast iron stoves, fireplaces, wall furnaces, wall furnaces, gas logs, vent free fireplaces, vent free fireboxes, fireplace inserts, floor furnaces, and cooking stoves.



Empire Classic Cast Iron Gas Stoves







    The Classic and Classic AH Cast Iron
Stoves, by White Mountain Hearth, are traditionally styled stoves containing a strikingly detailed ceramic fiber gas log
set. The result is an attractive, efficient heater that lends elegance to any decor.


    We offer these versatile stoves in five rich
porcelain-finishes, plus a flat black model you can leave as is or paint to match any décor. (Requires high-temperature coatings available from White Mountain Hearth and most hearth stores.) The optional stone inlays and matching floor pads add a touch of elegance. Order your Classic Cast Iron stove for natural gas or propane, and take charge with a thermostat, remote control, or remote control thermostat.


Empire Classic cast iron stoves deliver the finest choices in beauty and comfort while providing you with a cost efficient source of heat.  Available in
Vent-Free, Direct Vent and B-Vent Models.
Standard Classic      Empire cast stoves - Standard Classic cast iron stove
  • 3 Different Venting styles to make installation easy
  • Choose between five porcelain colors or flat black finish
  • Ceramic fiber log set secures to frame
  • Large fire viewing area
  • Variable heat output
  • Manual, wall switch, wall thermostat or remote control operation
  • Approved as a heater to the A.F.U.E. standard
  • Operates without electricity
  • Push-button ignition
  • Optional automatic blower
  • Safe operation with auto shut-off controls
  • Temperature Control For All Models- On/Off Millivolt





Firebox (Requires Stove Casting)



Classic Models
(On / Off Millivolt)
Model
Venting Type
   
CIBV-30 Vent Free Firebox Burner System
Available In Natural Gas Or Propane
(State On Order What Gas Type)
Standing Pilot / Piezo
Input: 21,000-30,000 BTU
Dimensions: 27-3/4" H x 25-1/2" W x 21" D
Gas Inlet: 1/2"

Click Here To Download An Owner's Manual
   


The installation must conform with local codes, or, in the absence of
local codes, with the National Fuel Gas Code, ANSI Z223.1/
NFPA54*.
*Available from the American National Standards Institute, Inc., 11
West 42nd St., New York, NY 10036.

State of Massachusetts: The installation must be made by a
licensed plumber or gas fitter in the Commonwealth of
Massachusetts.





Empire Classic Cast Iron Stove (Requires Firebox / Burner System)



Pick A Color For Your Stove!
Model
Color
   
CIFB-1Flat Black    
CIPB-1Porcelain Black
   
CIPG-1 Porcelain Green
   
CIPS-1 Porcelain Sand
   
CIPN-1 Porcelain Navy
   
CIPR-1 Porcelain Red
   





Blower



Model Description
Fits
Model
CIB-2 Automatic Blower All models





Remotes



ModelDescription
GWSG-T Wall Thermostat, Millivolt
TMV
Reed Switch Millivolt Wall Thermostat
FRBC Battery Operated Remote Control
Click Here For Manual
FRBTC Battery Operated Remote Control w/Thermostat
Click Here For Manual
FREC Electric Remote
FWS-1 Wall Switch





Stone Inlay




Variations will occur in color and veining of stone inlays.
ModelDescription
Color
  
CII-1 Stone Inlay:
Slate Gray Porcelain
   
CII-2 Stone Inlay:
Empress Green (Dark Green Marble)
   
CII-3 Stone Inlay:
Hunan Jade (White w/Green Vein Marble)
   
CII-4 Stone Inlay:
Gray Botticino (Gray/Cream Marble)
   
CII-5 Stone Inlay:
Azul (Black/Gray/Blue Granite)
   
CII-6 Stone Inlay:
Salome (Reddish Gray Marble)
   
CII-7Stone Inlay:
Black Swan (Ebony Polished Stone)
  





Important Information



On All Models
Due to high temperatures, the appliance should be located out of traffic and away from furniture and draperies.

Children and adults should be alerted to the hazards of high surface temperatures and should be kept away to avoid burns or clothing ignition.
Installation and repair should be done by a qualified service person.

The installation must conform to local codes.  In the absence of local codes, the installation must conform with American National Standard (National Fuel Gas Code) know as NFPA 54 and ANSIZ223.1 (latest edition) available from the American National Standards Institute, Inc., 11 West 42nd St. New York, NY 10036.

On B-Vent Models

B-Vent models are design certified in accordance with American National Standard Z21.11.1B- (1995) and CAN1-2.1-M89, CAN/CGA 1.17-M91 by Inchcape Testing/Warnock Hersey Inc., as a Vented Room Heater.

Note: A vent safety switch is standard on all models, automatically shutting the stove off in the event of a blocked flue or incorrect installation.  (Example: Attaching a 90 degree elbow directly to the draft diverter is an incorrect installation.)  The flue pipe diameter must be as large as the flue collar on the draft diverter and run as directly as possible to the chimney with a minimum of elbows.

The horizontal run of flue pipe must slope upward to the chimney at least 1/4" rise per foot of run, properly supported by metal straps, and enter the chimney so the end of the flue pipe is flush with the inner wall of the chimney.  Any flue pipe passing through walls and roof must be "B" Type vent.  The chimney must extend at least two feet above the roof and any object or building within 10 feet of the chimney.  The flue pipe must NOT have any open tees or be connected to the chimney of an existing fireplace.